YLCM Construction Machinery Co., Ltd. focuses on providing high-quality cooling and air conditioning system components for construction and mining machinery. With reliable quality and competitive prices, it serves mining companies, maintenance workshops and construction contractors in Central Asia, Russia, Africa and Southeast Asia, upholding the principles of integrity and long-term cooperation to provide cost-effective solutions. Below is the product classification information.
1.Air Conditioning Parts:
| 04120-21739 |
198-911-9142 |
20Y-810-1213 |
235-809-4640 |
2A5-979-1122ST |
426-07-32860 |
7835-47-6000CL |
| 12Y-979-1115 |
201-979-8903 |
20Y-810-1213CQ |
2A5-979-1113 |
423-07-31533 |
561-07-61103 |
ACF-KIT1-0KC |
| 14X-911-7103 |
201-979-8903CQ |
20Y-979-6111 |
2A5-979-1113CQ |
423-07-31533CQ |
561-07-61103AK |
ACF-KIT2-0KC |
| 14X-911-7200 |
208-979-7612 |
20Y-979-6111ST |
2A5-979-1122 |
423-S61-2111 |
566-07-81102 |
ND116410-2852 |
| 17A-911-7200 |
208-979-7612CQ |
20Y-979-6821 |
2A5-979-1122CQ |
423-S61-2111CL |
567-07-73412 |
ND263500-0763 |
| 17A-911-7201 |
208-979-7612ST |
20Y-979-8412 |
2A5-979-1122GS |
425-07-21111 |
7835-47-6000 |
X990017850CQ |
2.Water Pump:
| 2225152 |
6057479 |
377-7037 |
6151-62-1404 |
6215-65-1104 |
6933-61-1104 |
9-13612-802-0KF |
| 3520200 |
1-13610-804-0KF |
605-7481 |
6151-65-1105 |
6215-65-1304 |
8-94370-105-0KF |
ET945A038 |
| 3541672 |
258-80-53200 |
6150-61-1105 |
6162-63-7700 |
6218-61-1200 |
8-97321-508-3KF |
TC258H103551KF |
| 3557389 |
360-4174 |
6151-61-1105 |
6212-61-1704 |
6253-61-1100 |
8-97379-805-0KF |
YM129907-42002 |
3.Cooling Fan Motor:
| 203-03-71140 |
2A5-03-35321DY |
421-03-44030CL |
6212-62-4200 |
6755-61-7200 |
CU5586963CS |
KT1J700-3715-0JT |
| 207-03-71641 |
418-54-43300 |
423-03-D1102CL |
6212-62-6100 |
708-7W-00110 |
CU5624912CS |
P125S8-HO-CRDO0KC |
| 208-03-71121 |
418-54-43300CL |
426-56-21910 |
6240-61-6300 |
CU4937308CS |
KT1A700-3701-0JT |
X490041240KZ |
| 21T-03-31160 |
421-03-44030 |
6128-61-6100 |
6738-61-4123 |
CU4990291CS |
KT1G777-1743-0JT |
X490041240ST |
4.Coolant Tank:
| 14X-60-21111 |
195-03-22111 |
208-04-D5113ST |
20Y-06-15240 |
23E-43-13420 |
2A8-04-11131 |
3EB-36-22850KF |
| 14X-911-1161 |
201-03-71810 |
208-60-75111 |
20Y-06-15240GS |
2A5-01-00110 |
2A8-04-11131CL |
415-04-11117 |
| 14X-Y11-2110 |
201-03-71810AK |
208-60-75111CL |
20Y-06-15240ST |
2A6-03-11111 |
2A8-60-11113 |
417-03-10230 |
| 17A-03-41131 |
207-04-71210 |
209-03-41221 |
21N-60-41150 |
2A7-04-14112CL |
2A8-60-11113CL |
419-03-21320 |
| 17A-03-41142 |
207-04-78111CL |
20Y-03-61111 |
21U-04-31112 |
2A8-04-11130 |
3EB-04-51360KF |
419-03-21320CL |
| 17A-03-51951 |
207-04-D8110CL |
20Y-03-61111DY |
232-43-13601 |
2A8-04-11130CL |
3EB-36-11400KF |
419-03-21320GS |
|
5.Radiator Components:
| 11Y-03-34111 |
206-03-24110 |
208-03-75111CL |
20Y-03-43650DY |
22L-03-21112 |
3EC-04-31311KF |
423-03-41440NC |
| 17M-03-51112 |
206-03-24110DY |
208-03-75111DY |
20Y-03-43650ST |
22P-03-11111 |
3EC-04-51211KF |
ND116410-9980 |
| 195-03-63115 |
206-03-24110ST |
208-03-75111ST |
20Y-03-43651 |
3EA-04-51211KF |
423-03-41200 |
X211147476ST |
| 203-03-17211KZ |
207-03-75120 |
20Y-03-42452 |
20Y-03-43651DY |
3EB-04-51610KF |
423-03-41311 |
X211268173ST |
| 203-03-17211ST |
207-03-75121 |
20Y-03-42452DY |
20Y-03-43651ST |
3EB-04-52610KF |
423-03-41440 |
X212234601CL |
| 203-03-71774 |
208-03-75111 |
20Y-03-42452ST |
21T-03-31711 |
3EB-04-62111KF |
423-03-41440CL |
X810602401CL |
6.Dryer Assembly:
| 12Y-979-1140 |
423-07-31571 |
20Y-979-C210 |
234-A44-1500 |
23B-44-31520 |
23S-W90-5310 |
DM79443273 |
| 22L-979-2232 |
22L-979-2232KZ |
22L-979-2232ST |
234-44-42100 |
3FE-38-31510KF |
|
|
|
1. What thermal management components are essential for construction machinery?
Construction machinery requires coordinated cooling and AC systems to ensure engine, hydraulic, and cabin stability:
Radiators: Efficient heat dissipation for engine and hydraulic oil cooling.
Water Pumps: Maintain coolant circulation under high load and temperature.
Cooling Fan Motors: Intelligent airflow control to optimize energy use.
Coolant Tanks: Pressure-resistant, corrosion-proof reservoirs for reliable operation.
AC Components: Cabin comfort and high ambient temperature cooling.
Dryers: Maintain system moisture-free operation to protect AC performance.
2. How do I choose the right thermal management components for my machinery?
Selection depends on:
Operating conditions: Extreme heat, dust, humidity, or high altitude.
Cooling requirements: Engine power, hydraulic load, cabin cooling needs.
Compatibility: OEM specifications, part numbers, and system layout.
Maintenance goals: Long service life and minimal downtime.
3. What materials and technologies ensure YLCM components are durable?
Radiators: Aerospace-grade Al-Ti alloys, vacuum brazed for 45% larger heat exchange.
Pumps: Silicon carbide mechanical seals, CFD-optimized stainless steel impellers.
AC & Fans: Brushless DC motors, intelligent ECU control, IP68/IP69K protection.
Tanks & Dryers: High-density PE, UV-resistant, molecular sieve adsorption.
4. How do YLCM components improve energy efficiency?
Cooling fans save up to 40% energy with ECU stepless control.
Optimized pump flow reduces engine load while maintaining 320 L/min circulation.
AC systems with COP 3.8 provide stable cabin cooling with lower energy consumption.
5. Are YLCM thermal management solutions suitable for extreme environments?
Yes. All products withstand:
Temperature range: -40℃ to 105℃
Humidity: up to 95%
Continuous operation: 2,000+ hours
High-dust and high-pressure wash conditions (IP68/IP69K)
6. Can YLCM components be used with multiple machinery brands?
Yes. YLCM solutions are compatible with most major brands, including Komatsu, Caterpillar, Hitachi, Volvo, and more. Technical support is available for correct component selection.
7. What maintenance practices are recommended for YLCM thermal components?
Regular inspection for leaks, corrosion, or debris buildup.
Ensure fans and pumps operate smoothly; lubricate if applicable.
Replace AC dryer cartridges per manufacturer recommendations.
Monitor coolant levels and tank condition for pressure and UV damage.
8. How do YLCM integrated thermal systems enhance machinery performance?
CFD-optimized airflow reduces resistance by 30%.
Parallel flow channels increase heat dissipation by 45%.
Intelligent control units automatically optimize fan speed and pump flow, saving 35% energy.
System passes ISO 19453 vibration, thermal shock, and pressure pulse tests.
9. How quickly can I receive YLCM thermal management products?
YLCM offers fast worldwide delivery. Orders are processed promptly to minimize downtime, with support for both single-unit and bulk orders.
10. Why choose YLCM thermal management solutions over others?
Advanced design: Radiators, pumps, AC, and dryers engineered for extreme conditions.
Reliable quality: ISO certifications, endurance tests, long service life.
Environmental adaptability: IP68/IP69K protection, UV and corrosion resistance.
Global support: Partnered with 20+ international OEMs, 24h multilingual support.
High cost-effectiveness: Reduced energy consumption, lower total ownership costs.
YLCM thermal management solutions ensure stable, efficient, and durable operation of construction machinery under the harshest conditions, reducing maintenance costs and extending equipment life.